Repository navigation
Conversation
Signed-off-by: Saravana Periyasamy <saperiyasamy@nvidia.com>
Signed-off-by: Saravana Periyasamy <saperiyasamy@nvidia.com>
Signed-off-by: Saravana Periyasamy <saperiyasamy@nvidia.com>
Signed-off-by: Saravana Periyasamy <saperiyasamy@nvidia.com>
sara4dev
force-pushed
the
codex/node-local-fabric-ipc
branch
from
November 25, 2026 04:31
579ca6c to
9af9a67
Compare
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
What type of PR is this?
/kind bug
What this PR does / why we need it:
Stacks on kubernetes-sigs#1449 at
579ca6c1. The ComputeDomain plugin stays available on nodes without Fabric Manager hardware. The plugin detects hardware at startup and sends one node-local IMEX decision through CDI. Daemon startup, readiness, and channel preparation use the same decision.Special notes for your reviewer:
AI tooling assisted the implementation, tests, and PR draft.
Linux
go test -race ./...passed. Linuxgolangci-lint v2.13.2 run ./...reported zero issues. On an HGX A100 node without an MNNVL clique, the canary receivedNODE_LOCAL_FABRIC_IPC_ENABLED=truethrough CDI and started IMEX. The GPU-only control failed the FABRIC allocation as expected. An 8 MiB read and write passed between distinct GPUs.For 1 GiB copies, FABRIC averaged 3.96 ms and staged TCP averaged 636.40 ms. Each path used three warm-ups and ten timed copies. FABRIC recorded 13 GiB on source NVLink TX and destination RX. TCP recorded zero NVLink payload. The unsupported-node and host-managed paths have unit coverage.
Does this PR introduce a user-facing change?